CASCADE REFRIGERATION SYSTEMS

PRODUCT DESCRIPTION
We are engaged in offering quality Cascade Refrigeration System, which is a multistage application in which two separate refrigerant systems are interconnected in such a manner that one provides the means of heat rejection (condenser) for the other. Our Cascade Refrigeration System has a lower system which operates at a much lower temperature. The Cascade Refrigeration System, provided by us, comprises of additional feature, over compound systems for permitting the use of different refrigerants in each cycle of the cascade.

Why Our Cascade Refrigeration System?
• Robust body
• Multistage Application
• High performance
• Energy efficient
• Effective Cooling
• High Durability
• Low maintenance

TECHNICAL SPECIFICATIONS
Sub-Title
Parameter
High Side
Model
NAECS-01
-
Refrigeration / System
Refrigerant
R 404A / R-22
Temp. attained
-30 Deg Celsius
Low side chamber at -40 deg C
Evaporation temperature
-40 Deg Celsius
-50 Deg Celsius
Corresponding suction pressure
05 psig
05 psig.
Condensing temperature
+35 Deg Celsius
- 30 Deg Celsius
Discharge pressure
350 psig
120 psig
Discharge gas temperature
48 Deg Celsius
-35 Deg Celsius
Desuperheater
NA
Required
Compressor
Hermetically sealed, Emerson/ Danfoss or equivalent
Hermetically sealed, Emerson/ Danfoss or equivalent
Compressor oil
Standard
Standard
Oil separator
NA
Danfoss-OUB-1
Condenser
Air Cooled
Cascade condenser- tube in tube type/ PHE type
Drier
DM-50
DM-50
Evaporator
Tube-in-tube / Plate type heat exchanger
Forced convection air cooled
Expansion device
Thermostatic expansion valve
Capillary Tube
Accumulator
Copper / M.S. shell suction line accumulator provided.
-
Insulation
65 MM PUF
250 MM PUF
Controls & Indications
HP/LP Cut-out
Provided
Temperature
Digital Indicator with selector 
Pressure gauges 2 Nos. for suction and discharge
Digital Indicator with selector 
Pressure gauges 2 Nos. for suction and discharge
Electrical System
Supply
415 volts, 3 phase, 50 Hz
Input power
5.0 kW
-
Rated current
8.0 Amps.
-
Energy-meters
Provided for compressor.
Provided for compressor and heater
Construction
Outer body
1.2 thk CRCA, powder coated
Inner body
-
Stainless steel.
Size
2750x775 x1340 mm (L*D*H)
-
J. P. TECHNO INSTRUMENTS
 
Cam Anyalisis Apparatus
 
Cascade Refrigeration System
 
J. P. TECHNO INSTRUMENTS
953, Bazar Peth Road, Masur
Tal-Karad, Dist - Satara. (Mh)
Cell : + 91 - 98220 48448
Web : www.jptechnoindia.com
 
 
 
 
 
 
DOMESTIC REFRIGERATOR TRAINER

PRODUCT DESCRIPTION & PRINCIPLE OF OPERATION
This Refrigerator Works on simple Vapour Compression Cycle. Continuously circulating, evaporating, and condensing a fixed supply of refrigerant in a closed system accomplish mechanical refrigeration. Evaporating occurs at a low temperature and low pressure while condensation occurs at a high temperature and pressure. Thus, it is possible to transfer heat from an area of low temperature (i. e. refrigerator cabinet) to an area of high temperature (i.e. kitchen) Beginning the cycle at the evaporator inlet the low pressure liquid expands, absorbs heat, and evaporates, changing to a low pressure gas at the evaporator outlet. The Compressor pumps this gas from the evaporator through the accumulator increases its pressure, and discharges the high pressure gas to the condenser accumulator is designed to protect the compressor by preventing slugs of liquid refrigerant from passing directly into the compressor. An accumulator should be included on all systems subjected to varying load conditions or frequent compressor cycling. In the condenser, heat is removed from the gas which then condenses and becomes a high pressure liquid. In some systems this high-pressure liquid drains from the condenser into the liquid storage or receiver tank. On other systems, both the receiver and the liquid line valve are omitted. A heat exchanger between and the liquid line and the suction line is also an option item which may or may not be includes in a given system design. Between the condenser and the evaporator an expansion device is located. Immediately preceding this device is a liquid line strainer/ drier which prevent plugging of the valve or tube by retaining scale, dirt and moisture. The flow of refrigerant into the evaporator is controlled by the pressure differential across the expansion device or, in the case of a thermal expansion valve, by the degree of superheat of the suction gas. Thus, the thermal expansion valve shown requires a sensor bulb located at the evaporator outlet. In any case, the flow of refrigerant into the evaporator load increase as the evaporator load increases. As the high pressure liquid refrigerant enters the evaporator it is subjected to a much lower pressure due to the suction of the compressor and the pressure drop across the expansion device. Thus the refrigerant tends to expand and evaporate. In order to evaporate the liquid must absorb heat from the air passing over the evaporator.
Eventually the desired air temperature is reached and the thermostat or cold control will break the electrical circuit to the compressor motor and stop the compressor. As the temperature of the air through the evaporator rises, the thermostat or cold control remakes the electrical circuit. The compressor motor and starts, and the cycle continue

Capacity : 165 Litters Minimum.
Refrigerator : PANASONIC/ VIDEOCON/WHIRPOOL/ GOGREJ/ LG OR ANY EQUIVALENT make.
Power Source : 220- 240 V; 50HZ; 1 Phase, AC
Freezer : Ice Trays Provided Component
Shelf provided
Freezer door rack.
Refrigerator : Storage Shelves  Provided 
Shelf-half adjustable/full folding provided
Shelf Eggs provided
Shelf Bottle provided
Crisper Provided
Glass Shelf Provided
Capacity 142 Ltrs.
Heater for load : Provided.
Energy Meter Compressor : Provided
Energy Meter Heater : Provided
Pressure Gauges : 2 Nos Provided
1 No. for suction gas pressure
1 No for discharge gas pressure
Temperature : Digital Temperature Indicator with selector to display refrigerant temperatures at salient points.
Refrigerant : R-134 a
Non CFC & Environment friendly.

SET OF EXPERIMENTS
• To study construction and working of a domestic refrigerator
• To evaluate cooling capacity of the refrigerator at the ambient temperature.
• To evaluate the actual Co-efficient of Performance of the refrigeration system.
• To evaluate the theoretical Co-efficient of Performance of the refrigeration system.
• To plot the cycle on P-H & T-S charts.

J. P. TECHNO INSTRUMENTS
 
Domestic Refrigerator Trainer
 
Domestic Refrigerator Trainer
 
J. P. TECHNO INSTRUMENTS
953, Bazar Peth Road, Masur
Tal-Karad, Dist - Satara. (Mh)
Cell : + 91 - 98220 48448
Web : www.jptechnoindia.com
 
 
 
 
 
 
GENERAL CYCLE AIR CONDITIONING TEST RIG

PRODUCT DESCRIPTION:
The A.C. test rig works on simple vapour compression refrigeration cycle using R-134a as a refrigerant. The system is fabricated such that student can study all the air conditioning processes. It is also useful to understand working of all the components of system, their performance and control etc.
All the components are mounted on the display board, so that students can observe their working easily.

TECHNICAL SPECIFICATIONS:
CAPACITY
:
1/3 TR@RATED TEST CONDITIONS
COMPRESSOR
:
HERMETICALLY SEALED. MAKE: EMERSON CLIMATE TECH.OR ANY EQUIVALENT MAKE.
CONDENSER
:
FORCED CONVECTION AIR COOLED.
CONDENSER FAN
:
AXIAL FLOW.
DRIER/ FILTER
:
PROVIDED.
EXPANSION DEVICE
:
CAPILLARY TUBE.
EVAPORATOR
:
FORCED CONVECTION AIR COOLED.
EVAPORATOR FAN
:
CENTRIFUGAL / AXIAL FLOW TYPE
DEHUMIDIFIER OR REHEATER
:
 FINNED TYPE AIR HEATER.
HUMIDIFIER
:
PROVIDED
REFRIGERANT
:
R-134 a.
HP / LP CUT-OUT
:
ALCO/ OR DANFOSS / OR INDFOSS OR ANY EQUIVALENT MAKE.
TEMPERATURE
:
6 CHANNEL FACILITY WITH DIGITAL DISPLAY.
PRESSURE
:
2 NOS.; DIAL TYPE PRESSURE GAUGES.
REFRIGERANT FLOW
:
GLASS TUBE ROTAMETER PROVIDED.
AIR TEMPERATURE
:
DBT & WBT MEASUREMENT BY SLING PSYCHROMETER.
AIR FLOW MEASUREMENT
:
BY INCLINED TUBE MANOMETER.
SUPPLY
:
220-240 VOLTS, 50 HZ, 1 PHASE.
INPUT POWER
:
0.75 KW.
RATED CURRENT
:
4 AMPS.
INDICATING LAMPS
:
PROVIDED FOR COMPRESSOR AND HEATER.
ENERGY-METER
:
RANGE 0-20 A; PROVIDED FOR COMPRESSOR
MATERIAL
:
PANEL: 1.2 MM THICK CRCA
OUTER FINISH
:
POWDER COATING

LIST OF EXPERIMENTS:
• To evaluate the tonnage capacity of the air conditioning system by enthalpy difference method.
• To evaluate actual and theoretical C.O.P. of the system.
• To plot the refrigeration cycle on P-H & T-S charts.
• To plot the psychometric processes on psychometric charts.

J. P. TECHNO INSTRUMENTS
 
Domestic Refrigerator Trainer
 
Domestic Refrigerator Trainer
 
J. P. TECHNO INSTRUMENTS
953, Bazar Peth Road, Masur
Tal-Karad, Dist - Satara. (Mh)
Cell : + 91 - 98220 48448
Web : www.jptechnoindia.com
 
 
 
 
 
 
ICE PLANT TEST RIG 24 KG PER DAY

PRODUCT DESCRIPTION:
The Ice Plant Test rig works on simple vapour compression refrigeration cycle and uses R134-a or R404-A as a refrigerant. These are environment friendly. The system is fabricated such that students can observe and study ice formation process. It is also useful to understand working of vapour compression system, its performance and controls used. The arrangement of parts such that, all the parts are visible and working can be easily understood.

TECHNICAL SPECIFICATIONS:
Ice Production Capacity : 24 kg in a day of 24 hrs.
After attaining brine temperature of -5 deg C, ice cans will be loaded.
Number of ice cans = 4 nos; Ice qty per can=0.5 kg
Ice production per batch = 2 kg
Cycle time per batch = 2 hrs.
Compressor : Hermetically sealed.
Emerson/ Tecumseh/ Danfoss or equivalent make.
Condenser : Forced convection air cooled
Condenser fan : Axial flow type
Evaporator : Immersed (Refrigeration grade copper tube); Direct expansion type; 3/8” OD x 35’
Drier/ filter : Provided; Molecular sieve type
Expansion device : Capillary tube
Insulation : 65 mm thick, Polyurethane foam (PUF)
Refrigerant : R 134a/404a
Temperature : Temperature indicator with 6 no. of selector points provided
Pressure : 2 Nos. for suction and discharge
Brine Solution : Ethylene Glycol + Water
Supply : 230 Volts, 50 Hz, 1 phase.
Input power : 400 Watts.
Rated current : 3.0 Amps
Stirrer Motor : Provided.
Energy-meter : For compressor provided.
Outer body : 1.2 mm thick CRCA
Brine Tank : SS 304/ PVC

LIST OF EXPERIMENTS:
TO EVALUATE CAPACITY OF THE ICE PLANT.
TO CALCULATE C.O.P. OF THE SYSTEM.
TO PLOT SYSTEM PERFORMANCE ON P-H CHART.

J. P. TECHNO INSTRUMENTS
 
Ice Plant Test Rig
 
Ice Plant Test Rig
 
J. P. TECHNO INSTRUMENTS
953, Bazar Peth Road, Masur
Tal-Karad, Dist - Satara. (Mh)
Cell : + 91 - 98220 48448
Web : www.jptechnoindia.com
 
 
 
 
 
 
MECHANICAL HEAT PUMP

PRODUCT DESCRIPTION:
All the components of heat pump Test Rig are displayed on powder coated fabricated stand. The primer consists of a hermetically sealed compressor, heat rejection chamber, drier-filter, expansion device, and heat absorption chamber. Hot vapours from the heat absorption chamber in the tank are sucked by the compressor, are compressed & sent to the heat rejection chamber. Liquid emerging out from the heat rejection chamber passes through the expansion device; it is throttled to low pressure & temperature & sent to heat absorption device where it boils. A drier filter is in the way to throttling device. Separate pressure gauges are provided to measure heat absorption device & heat rejection device Pressures at various locations. Energy meter is provided to measure energy consumed by compressor. Rotameter in the liquid line is incorporated to measure the refrigerant flow. Digital temperature indicator displays temperatures at various locations as per the selection viz. temperature before & after compressor and before & after expansion.

SPECIFICATIONS OF THE HEAT PUMP TEST RIG:

HEAT PUMP RATING
:
500 WATTS GROSS HEAT REJECTION AT RATED TEST CONDITIONS
compressor
:
HERMETICALLY SEALED
emerson climate technologies make INDIA LTD.OR EQ. MAKE
HEATREJECTION CHAMBER
:
WATER COOLED PROVIDED
drier filter
:
provided
EXPANSION DEVICE
:
CAPILLARY TUBE
HEATABSORPTION CHAMBER
:
Immersed TYPE (REFRIGERANT GRADE COPPER TUBE)
DIRECT EXPANSION TYPE PROVIDED
REFRIGERANT
:
R-134 A
REFRIGERANT flow measurement
:
GLASS TUBE ROTAMETER.
temp. indicator
:
DIGITAL TEMP. INDICATOR provided
 
pressure INDICATION
:
DIAL TYPE PRESSURE GAUGES: 2 NOS
ENERGYMETER
:
PROVIDED FOR THE COMPRESSOR
SUPPLY
:
230 VOLTS, 1 PH, 50 HZ AC















LIST OF EXPERIEMNTS:

• To evaluate the COP of the system of heating & cooling cycle.
• To calculate CARNOT COP.
• To plot the actual Refrigeration Cycle on P-H chart.
• To study various components and controls used in heat pump.

J. P. TECHNO INSTRUMENTS
 
Mechanical Heat Pump
 
Mechanical Heat Pump
 
J. P. TECHNO INSTRUMENTS
953, Bazar Peth Road, Masur
Tal-Karad, Dist - Satara. (Mh)
Cell : + 91 - 98220 48448
Web : www.jptechnoindia.com
 
 
 
 
 
 
RE-CIRCULATION TYPE AIR CONDITIONING TEST RIG

PRODUCT DESCRIPTION:
Test rig enables to study the psychometric process with recirculation of air. The trainer works on simple vapor compression refrigeration Cycle using R 22 as a refrigerant.
The system is fabricated such that student can study all the air conditioning Processes. It is also useful to understand working of all the components of system, their performance and control etc. All the components are mounted on the display board, so that students can observe their working easily.

TECHNICAL SPECIFICATIONS:
CAPACITY
:
1.0 TR @RATED TEST CONDITIONS
COMPRESSOR
:
HERMETICALLY SEALED. MAKE: EMERSON CLIMATE TECH.OR ANY EQUIVALENT MAKE.
CONDENSER
:
FORCED CONVECTION AIR COOLED.
CONDENSER FAN
:
AXIAL FLOW.
DRIER/ FILTER
:
PROVIDED.
EXPANSION DEVICE
:
CAPILLARY TUBE.
EVAPORATOR
:
FORCED CONVECTION AIR COOLED.
EVAPORATOR FAN
:
AXIAL FLOW TYPE
DEHUMIDIFIER OR REHEATER
:
1000 WATTS; FINNED TYPE.
HUMIDIFIER
:
PROVIDED
REFRIGERANT
:
R-22.
HP / LP CUT-OUT
:
ALCO/ OR DANFOSS / OR INDFOSS OR ANY EQUIVALENT MAKE.
TEMPERATURE
:
6 CHANNEL FACILITIES WITH DIGITAL DISPLAY.
PRESSURE
:
2 NOS.; DIAL TYPE PRESSURE GAUGES.
REFRIGERANT FLOW
:
GLASS TUBE ROTAMETER PROVIDED.
AIR TEMPERATURE
:
DBT & WBT MEASUREMENT BY SLING PSYCHROMETER.
AIR FLOW MEASUREMENT
:
BY INCLINED TUBE MANOMETER
SUPPLY
:
220-240 VOLTS, 50 HZ, 1 PHASE.
INPUT POWER
:
PROVIDED FOR COMPRESSOR AND HEATER.
RATED CURRENT
:
PROVIDED FOR COMPRESSOR
INDICATING LAMPS
:
PANEL: 1.2 MM THICK CRCA
ENERGY-METER
:
POWDER COATING
MATERIAL
:
PROVIDED.
OUTER FINISH
:
POWDER COATING

LIST OF EXPERIMENTS:
• Cooling of fresh air with full exhaust. (Summer experiment)
• Heating of fresh air with full exhaust. (Winter experiment)
• Humidification of air.
• Cooling or heating the air with partial recirculation.
   (Calculations for mixing of two air streams having different characteristics.)
• Cooling of air with full re-circulation (operation of the system as a window air conditioner.)

J. P. TECHNO INSTRUMENTS
 
Re-Circulation Type Air Conditioning Test Rig
 
Re-Circulation Type Air Conditioning Test Rig
 
J. P. TECHNO INSTRUMENTS
953, Bazar Peth Road, Masur
Tal-Karad, Dist - Satara. (Mh)
Cell : + 91 - 98220 48448
Web : www.jptechnoindia.com
 
 
 
 
 
 
REFRGERATION TEST RIG

PRODUCT DESCRIPTION:
The Refrigeration Test Rig works on vapor compression cycle. The refrigeration (i.e. process of maintaining a closed space temperature below ambient temperature) is accomplished by continuously circulating, evaporating and condensing a fixed supply of refrigerant in a closed system. Evaporation occurs at a low temperature and low pressure while condensation occurs at a high temperature and pressure. Thus it is possible to transfer heat from an area of low temperature (in this case calorimeter) to an area of high temperature (the surroundings).
The required instrumentation is provided to measure the various parameters at different points. This includes pressure gauges, temperature indicators and controller, energy-meters, heater for applying load and flow meter to measure the refrigerant flow

TECHNICAL SPECIFICATIONS OF REFRIGERATION TEST RIG
CAPACITY : 500 WATTS AT RATED TEST CONDITIONS.
REFRIGERANT : R-134 a
 COMPRESSOR : HERMETICALLY SEALED
Make: EMERSON CLIMATE TECHNOLOGIES LTD.OR EQUIVALENT.
CONDENSER : FORCED CONVECTION AIR COOLED
CONDENSER FAN MOTOR : INDUCTION TYPE
DRIER / FILTER : PROVIDED                           
EXPANSION DEVICE : CAPILLARY TUBE
REFIGERANT FLOW MEASURMENT : GLASS TUBE ROTAMETER
EVAPORATOR : FORCED CONVECTION AIR COOLED.
HP/LP CUTOUT : PROVIDED
PRESSURE INDICATION : PRESSURE GAUGES, 2NOS PROVIDED
ENERGY METER   2 NOS PROVIDED. EACH ONE FOR COMPRESSOR & HEATER
TEMPERATURE CONTROL OF THE TEST CHAMBER : AUTOMATIC BY TEMPERATURE CONTROLLER
SUPPLY : 230 VOLTS, 50HZ, 1 PHASE, AC.
CONSTRUCTION : MAIN BODY: 18 G CRCA, POWDER COATED.
CALORIMETER: STAINLESS STEEL

LIST OF EXPERIEMNTS:
• To evaluate the cooling capacity in Watts & in Tons of the system.
• To evaluate actual and theoretical C.O.P. of Vapor Compression Cycle.
• To plot the actual Refrigeration Cycle on P-H chart.
• To study various components and controls used in Vapor Compression Cycle.

J. P. TECHNO INSTRUMENTS
 
Refrgeration Test Rig
 
Refrgeration Test Rig
 
J. P. TECHNO INSTRUMENTS
953, Bazar Peth Road, Masur
Tal-Karad, Dist - Satara. (Mh)
Cell : + 91 - 98220 48448
Web : www.jptechnoindia.com
 
 
 
 
 
 
VAPOUR ABSORPTION TEST RIG

PRODUCT DESCRIPTION
“Vapour Absorption Refrigerator” earlier known as “Electrolux” refrigerator is a self contained refrigerator working on absorption technology. In the absence of a compressor or pump, the circulation takes place by density difference. The system is pre-charged with three fluids namely water, ammonia and hydrogen. Hydrogen is used as an “inert gas” and does not undergo any phase change and heat transfer processes. Its purpose is to keep the pressure of the system constant. It uses an electrically operated generator, where, the ammonia vapours dissolved in water are separated and pure ammonia vapours enter the condenser. In the condenser, the high pressure vapours reject its latent heat to the surroundings and get liquefied. The liquid ammonia expands through expansion device where its pressure and temperature is reduced and cold low pressure vapour enters the evaporator where it absorbs heat from the space to be cooled and then vaporized ammonia absorbs in water. This strong solution then enters the generator and the cycle repeats.

PRINCIPLE OF OPERATION
Electrolux principle works on 3-fluid system. There is solution circulation pump. Total pressure is the same throughout the system. The third fluid remains mainly in the evaporator thus reducing partial pressure of refrigerant to enable it to evaporate at low pressure and hence low temperature.
The schematic diagram of the Electrolux refrigerator working on NH3-H2O system with H2 as the third fluid is shown in figure. Liquid NH3 evaporates in the evaporator in the pressure of H2.Hydrogen is chosen as it is non –corrosive and insoluble in water.
A thermosyphon bubble pump is used to lift the weak aqua from the generator to the separator. The discharge tube from the evaporator the generator is extended down below the liquid level in the generator. The bubbles rise and carry slugs of weak NH3-H2O solution into the separator.

Two U-bends are provided as vapour- locks to prevent H2 from getting into the high side or solution circuit.

Partial pressure of H2 provides the pressure difference of NH3 between the condenser and evaporator. Accordingly, we have:

In condenser pure NH3 vapour pressure = Total pressure
In evaporator NH3 vapour pressure = Total pressure - partial pressure H2

For example, consider the condenser temperature at 50 0C, and evaporator temperature as -15 0C. The corresponding vapour pressures of NH3 are:
Condenser, Pk = 20.33bar; Evaporator outlet, Po2 = 2.6bar
The approximate pressures in various parts of the system then will be as given in the table.

Section
NH3
H2O
H2
Total
Condenser
20.33
0
0
20.33
Evaporator inlet
1.516
0
18.814
20.33
Evaporator outlet
2.36
0
17.97
20.33
Generator top
15.54
4.79
0
20.33

It has been assumed that vapours leaving generator top are in equilibrium with entering rich solution at 40 C, at which temperature saturation pressure of NH3is 15.45bar. It has also been assumed that the temperature at evaporator inlet is -25 C at which temperature saturation pressure of NH3 is 1.516bar.

TECHNICAL SPECIFICATIONS OF VAPOUR ABSORPTION SYSTEM

GROSS VOLUME : 41 LITERS
REFRIGERANT : WATER, AMMONIA, HYDROGEN
GENERATOR : ELECTRICALLY HEATED
CONDENSER : NATURAL CONVECTION TYPE
EVAPORATOR : NATURAL CONVECTION TYPE
MATERIAL OF
CONSTRUCTION SUPPLY
:
:
M.S.
230 VOLTS, 50 HZ, 1 PH
ENERGY CONSUMPTION : 1.07 KWH PER 24 HRS
ENERGYMETER : PROVIDED
TEMPERATURE INDICATOR : DIGITAL INDICATOR AT THE SALIENT POINTS

LIST OF EXPERIMENTS
• To study construction and working of a vapour absorption refrigerator
• To evaluate performance of the refrigerator by calculating the C.O.P of the system.

J. P. TECHNO INSTRUMENTS
 
Vapour Absorption Test Rig
 
Vapour Absorption Test Rig
 
J. P. TECHNO INSTRUMENTS
953, Bazar Peth Road, Masur
Tal-Karad, Dist - Satara. (Mh)
Cell : + 91 - 98220 48448
Web : www.jptechnoindia.com
 
 
 
 
 
 
VORTEX TUBE TEST RIG

PRODUCT DESCRIPTION
The Vortex Tube Test Rig is one of the non- conventional methods of cooling which has no moving parts. It requires only source of compressed air. Through this tube, when air is admitted at high pressure, from one end, hot sir is discharged and from the other end, cold air comes out. The test rig is designed such that all the performance can be evaluated.

CUSTOMER SCOPE
Electrical power point 230 volts, 50 HZ, 1 ph, with 16 amps MCB.
Clear space of 3 m x 2 m.
Compressed air supply at 5 bar & 50 CFM

LIST OF EXPERIMENTS
• To understand the principle of working Vortex Tube.
• To evaluate Adiabatic Efficiency of the system.
• To evaluate C.O.P. of the system.
• To find out Refrigeration Effect per kg of air supplied.

SPECIFICATIONS

Parameter Description
Material of construction of the vortex tube M.S. tube With inlet nozzle and diaphragm
Temperature measurement Digital led display provided
Pressure measurement Dial type pressure gauge provided or manometer
Arrangement for air flow measurement Provided.
Air flow variation Valve provided
General arrangement Integral unit mounted on suitable panel
Supply Compressed air supply at 10 bar
J. P. TECHNO INSTRUMENTS
 
Vortex Tube Test Rig
 
Vortex Tube Test Rig
 
J. P. TECHNO INSTRUMENTS
953, Bazar Peth Road, Masur
Tal-Karad, Dist - Satara. (Mh)
Cell : + 91 - 98220 48448
Web : www.jptechnoindia.com
 
 
 
 
 
 
WATER COOLER TEST RIG

PRODUCT DESCRIPTION
‘THE WATER COOLER’ Test Rig enables students to study and understand Vapor Compression Cycle, its components, principle and working. All the components are mounted on rigid steel frame. The trainer consists of a hermetically sealed compressor, forced convection air-cooled condenser, filter / drier, flow meter, expansion device and coil wound type evaporator. Separate pressure gauges are provided to record suction and discharge pressures and digital temperature indicators for various temperatures. The refrigerant used is R-134 which is environment friendly. The water cooler consists of an insulated stainless steel tank around which evaporator tubes are wound and soldered. The tubes are made of refrigerated grade annealed copper tubes. This is a direct expansion type evaporator. The heat absorbed by the refrigerant is passed through water which is continuously flowing.

TECHNICAL SPECIFICATIONS OF WATER COOLER TEST RIG
WATER COOLER : “ BLUE STAR”/ VOLTAS OR Equivalent  MAKE
WATER STORAGE : 20 LITERS
REFRIGERANT : R-134 a
OUTER BODY & INNER TANK : STAINLESS STEEL
 COMPRESSOR : HERMETICALLY SEALED; EMERSON CLIMATE TECHNOLOGIES OR EQUIVALENT
CONDENSER : FORCED CONVECTION  AIR COOLED
CONDENSER FAN MOTOR : 1/20 HP X 1400 RPM; INDUCTION TYPE
DRIER / FILTER : PROVIDED
EXPANSION DEVICE : CAPILLARY TUBE
PRESSURE INDICATION : PRESSURE GAUGES, 2NOS PROVIDED
TEMPERATURE INDICATION : DIGITAL TEMPERATURE INDICATOR FOR REFRIGERANT TEMPERATURES AND WATER TEMPERATURE.
ENERGY METER : FOR COMPRESSOR : PROVIDED
TEMPERATURE CONTROL OF THE WATER COOLER : THERMOSTAT PROVIDED.
SUPPLY : 230 VOLTS, 50HZ, 1 PHASE, AC.

LIST OF EXPERIEMNTS
• To evaluate the cooling capacity of water cooler.
• To evaluate actual and theoretical C.O.P. of Vapor Compression Cycle.
• To plot the actual Refrigeration Cycle on P-H chart.
• To study various components and controls used in Vapor Compression Cycle.
J. P. TECHNO INSTRUMENTS
 
Water Cooler Test Rig
 
Water Cooler Test Rig
 
J. P. TECHNO INSTRUMENTS
953, Bazar Peth Road, Masur
Tal-Karad, Dist - Satara. (Mh)
Cell : + 91 - 98220 48448
Web : www.jptechnoindia.com
 
 
 
 
 
 
WINDOW AIR CONDITIONER TEST RIG

PRODUCT DESCRIPTION:
The Window AC test rig is designed and manufactured such that the students can understand construction and working of a window type air conditioner and conduct the trial on it to evaluate performance of the same. The window AC is fixed in a rigid angle frame, with its cover cut half open to reveal the internal parts of the AC. The required pressure and temperature tapings are drawn for measurement of pressures and temperatures at salient points. Energy meter is provided for recording compressor energy consumption. A sling psychrometer is provided for measurement of inlet and outlet Dry-bulb & wet bulb temperature. With the help of manometer, velocity of air and consequently the flow rate of air can be determined.

TECHNICAL SPECIFICATIONS

Capacity : 1.0 TR at rated test conditions*
Compressor : Rotary type; Hermetically sealed. 
Condenser : Forced convection air cooled
Condenser fan : Axial flow type.
Evaporator : Forced convection air cooled.
Evaporator fan : Centrifugal type
Drier/ filter : Molecular sieve type.
Expansion device : Capillary Tube
Refrigerant : R-22
Temperature : Sling Psychrometer for air temperatures & Digital Indicator for refrigerant temperatures.
Velocity : By inclined tube manometer
Pressure : Pressure gauges 2 Nos at suction & discharge
Supply : 220-240 Volts, 50 Hz, 1 phase.
Input power : 1.2 kW
Rated current : 6.0 Amps.
Energy-meter : Provided for compressor
Material : Panel: 1.2 mm thick CRCA
Outer finish : Powder coating

LIST OF EXPERIMENTS:
• To determine Tonnage capacity of the Window type Air Conditioner by enthalpy
   difference method.
• To determine actual C. O. P & theoretical C. O. P of the cycle.
• To plot operating cycle on P-H chart.
J. P. TECHNO INSTRUMENTS
 
Window Air Conditioner Test Rig
 
Window Air Conditioner Test Rig
 
J. P. TECHNO INSTRUMENTS
953, Bazar Peth Road, Masur
Tal-Karad, Dist - Satara. (Mh)
Cell : + 91 - 98220 48448
Web : www.jptechnoindia.com
 
 
 
 
 
J.P.TECHNO INSTRUMENTS
 
www.heattransferlab.in
www.steampowerplants.net
www.fluidmachines.net
J.P.TECHNO INSTRUMENTS
   
We are Leading Manufactures of Educational Training Equipments and our setup is situated at Satara (MAHARASHTRA, INDIA)
Designed by : MID Hosted by : PBD Promoted by : GID